Starting with Can do the following operations Operation notes
PM3 fw 1-299 Change to Model A Op 1:Set local model type.Give warning that a factory reset or battery power loss will revert to how it was programmed at Concept2 and may need to be reconverted.
    Change to Model B/C Op 1 
    Change to Model D/E/Dynamic Op 1
       
PM3A FW 300-699 Change to Model A Op 2: Set local machine type and in user NV.  Give warning that a factory reset will revert to how it was programmed at factory and may need to be reconverted.
    Change to Model B/C Op 2 
    Change to Model D/E/Dynamic Op 2
    SkiErg Conversion Op 3: Set to Model D/E for safety; erase and burn SkiErg firmware 7xx
       
PM3A FW 700-900 Change to Model A Op 4: Set to Model A, then reload firmware for rowing; give warning about factory reset
  (skierg) Change to Model B/C Op 5: Set to Model B/C, then reload firmware; give warning about factory reset
    Change to Model D/E/Dynamic OP 6: Set to Model D/E/Dynamic for safety then reload rwoing fiwmare; give warning about factory reset
       
       
       
       
PM4 fw 1-299 Change to Model A Op 1:Set local model type.Give warning that a factory reset or battery power loss will revert to how it was programmed at Concept2 and may need to be reconverted.
    Change to Model B/C Op 1 
    Change to Model D/E/Dynamic Op 1
       
PM4A FW 300-699 Change to Model A Op 2: Set local machine type and in user NV.  Give warning that a factory reset will revert to how it was programmed at factory and may need to be reconverted.
    Change to Model B/C Op 2 
    Change to Model D/E/Dynamic Op 2
    SkiErg Conversion Op 3: Set to Model D/E for safety; erase and burn SkiErg firmware 7xx
       
PM3A FW 700-900 Change to Model A Op 4: Set to Model A, then reload firmware for rowing; give warning about factory reset
  (skierg) Change to Model B/C Op 5: Set to Model B/C, then reload firmware; give warning about factory reset
    Change to Model D/E/Dynamic OP 6: Set to Model D/E/Dynamic for safety then reload rowing firmware; give warning about factory reset
       
PM5v1 1-150 Change to Model A Op 7: Set to Model A; give warning about Factory Reset and also "may not work at slow pace on Model A".
  (rower) Change to Model B/C OP 2
    Change to Model D/E/Dynamic Op 2
    SkiErg Conversion Op 3
       
PM5v1 700-850 Change to Model A Op 4
  (skierg) Change to Model B/C Op 5
    Change to Model D/E/Dynamic Op 6
  BELOW NOT FINISHED  
PM5v2 151-299 Change to Model A  
  Rowing Change to Model B/C  
    Change to Model D/E/Dynamic  
    SkiErg Conversion  
    (Omega Conversion)  
       
       
PM5v2 850-990 Change to Model A  
  (skierg) Change to Model B/C  
    Change to Model D/E/Dynamic  
    (Omega Conversion)  
       
PM5v2 300-450 Change to Model A  
  (omega) Change to Model B/C  
    Change to Model D/E/Dynamic  
    SkiErg Conversion